Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38520434

RESUMO

BACKGROUND: Past clinical trials have shown the benefit of implantable cardioverter-defibrillators (ICDs) for reducing sudden cardiac death in at-risk patients. However, heart failure management and ICD technology have changed since these trials were first published. An updated assessment of ICD mortality benefit is needed. OBJECTIVES: The purpose of this study was to compare mortality rates between patients with a primary prevention (PP) indication for an ICD who did or did not receive an ICD using a contemporary, real-world data set. METHODS: Data was obtained from a large electronic health record data set covering patients in the United States from 2012 through 2020 who had a PP indication for an ICD and survived at least 1-year postindication. RESULTS: A total of 25,296 patients were identified as having a PP indication for ICD implantation, of which 2,118 (8.4%) were treated with an ICD within a year. Treated patients were younger than nontreated patients (63.4 years vs 66.1 years) with a smaller proportion of women (25.0% vs 36.7%). After 4-to-1 propensity matching, treated patients had similar clinical characteristics to nontreated patients. A Cox proportional hazard model estimated a 24.3% lower risk of all-cause mortality in patients when treated vs not treated with an ICD (HR: 0.757; CI: 0.678-0.835; P <0.001). There was no detectable difference in ICD benefit between patients with ischemic and nonischemic heart disease (P = 0.50). CONCLUSIONS: ICD treatment of patients with a PP indication is associated with improved mortality even in the context of evolving adjunctive HF treatment, consistent with earlier landmark trials.

2.
J Cardiovasc Electrophysiol ; 35(2): 230-237, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047467

RESUMO

INTRODUCTION: The extravascular implantable cardioverter defibrillator (EV ICD) has extended projected battery longevity compared to the subcutaneous implantable cardioverter defibrillator (S-ICD). This study used modeling to characterize the need for generator changes, long-term complications, and overall costs for both the EV ICD and S-ICD in healthcare systems of various countries. METHODS: Battery longevity data were modeled using a Markov model from averages reported in device labeling for the S-ICD and with engineering estimates based on real life usage from EV ICD Pivotal Study patient data to introduce variability. Clinical demographic data were derived from published literature. The primary outcomes were defined as the number of generator replacement surgeries, complications, and total healthcare system costs due to battery depletion over the expected lifetime of patients receiving EV ICD or S-ICD therapy. RESULTS: Average modeled battery longevity was determined to be 7.3 years for the S-ICD versus 11.8 years for the EV ICD. The probability of a complication after a replacement procedure was 1.4%, with an operative mortality rate of 0.02%. The use of EV ICD was associated with 1.4-1.6 fewer replacements on average over an expected patient lifetime as compared to S-ICD and a 24.3%-26.0% reduction in cost. A one-way sensitivity analysis of the model for the US healthcare system found that use of an EV ICD resulted in a reduction in replacement surgeries of greater than 1 (1.1-1.6) along with five-figure cost savings in all scenarios ($18 602-$40 948). CONCLUSION: The longer projected battery life of the EV ICD has the potential to meaningfully reduce long-term morbidity and healthcare resources related to generator changes from the perspective of multiple diverse healthcare systems.


Assuntos
Desfibriladores Implantáveis , Humanos , Falha de Equipamento , Cardioversão Elétrica/efeitos adversos , Previsões , Redução de Custos
3.
J Med Econ ; 27(1): 62-68, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38084737

RESUMO

BACKGROUND: VAD therapy has revolutionized the treatment of end-stage heart failure, but infections remain an important complication. The objective of this study was to characterize the clinical and economic impacts of VAD-specific infections. METHODS: A retrospective analysis of a United States claims database identified members ≥ 18 years with a claim for a VAD implant procedure, at least 6 months of pre-implant baseline data, and 12 months of follow-up between 1 June 2016 and 31 December 2019. Cumulative incidence of infection was calculated. Infection and non-infection cohorts were compared regarding mortality, healthcare utilization, and total cost. Regression models were used to identify risk factors associated with infections and mortality. RESULTS: A total of 2,259 patients with a VAD implant were included, with 369 experiencing infection (12-month cumulative incidence 16.1%). Patients with infection were 2.1 times more likely to die (p < 0.001, 95% CI [1.5-2.9]). The mean 12-month total cost per US patient was $354,339 for the non-infection cohort and $397,546 for the infection cohort, a difference of $43,207 (p < 0.0001). CONCLUSIONS: VAD infections were associated with higher mortality, more healthcare utilization, and higher total cost. Strategies to minimize VAD-specific infections could lead to improved clinical and economic outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estados Unidos/epidemiologia , Estudos Retrospectivos , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Revisão da Utilização de Seguros , Fatores de Risco , Resultado do Tratamento
5.
BMC Cardiovasc Disord ; 23(1): 8, 2023 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624380

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is recommended to treat paroxysmal and persistent atrial fibrillation (AF). This analysis aimed to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and point-by-point radiofrequency ablation (RFA). METHODS: The discrete event simulation used PVI procedure times from the FREEZE Cohort study to establish the electrophysiology (EP) lab occupancy time. 1000 EP lab days were simulated according to an illustrative German hospital, including 3 PVI cases per day using CBA at one site and RFA at the other. RESULTS: The analysis included 1560 CBA patients and 1344 RFA patients from the FREEZE Cohort. Some baseline patients' characteristics were different between groups (age, AF type, and some concomitant diseases), without being statistically associated to ablation procedure time. Mean procedure time was 122.2 ± 39.4 min for CBA and 160.3 ± 53.5 min for RFA (p < 0.0001). RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the simulated period (1285 h with RFA and 253 h with CBA). 70.7% of RFA lab days included overtime versus 25.7% for CBA. CBA was associated with more days with an additional hour at the end of the EP lab shift compared to RFA (47.8% vs 11.5% days with one hour left, respectively). CONCLUSION: CBA is faster and more predictable than point-by-point RFA, and enables improvements in EP lab efficiency, including: fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage. Clinical trial registration NCT01360008 (first registration 25/05/2011).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Estudos de Coortes , Criocirurgia/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Eletrofisiologia , Resultado do Tratamento , Recidiva
6.
PLoS One ; 17(11): e0277685, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36395168

RESUMO

Cost collection using UB-04 forms for economic evaluation is challenging, as UB-04 collection is time and effort intensive and compliance is imperfect. Alternative data sources could overcome those challenges. The objective of this study is to determine the usefulness of UB-04 data in estimating hospital costs compared to clinical case report form (CRF) data. Health care utilization costs were compared from financial information in UB-04s and from an assignment process using CRF data, from the WRAP-IT (23 infections) and the Micra IDE trials (61 adverse events and 108 implants). Charge-based costs were calculated by multiplying charges in UB-04s and hospital-specific Cost-to-Charge ratios from the Centers for Medicare and Medicaid Services cost reports. The cost assignment process used clinical information to find comparable encounters in real world data and assigned an average cost. Paired difference tests evaluated whether both methods yield similar results. The mean difference in total infection related costs between methods in the WRAP-IT trial was $152 +/-$22,565. In the Micra IDE trial, the mean difference in total adverse event related costs between methods was -$355 +/-$8,298 while the mean difference in total implant related costs between methods was $-3,488 +/-$13,859. Wilcoxon tests and generalized linear models could not reject the difference in costs between methods in the first two cases. Cost assignment methods achieve results similar to costs obtained through UB-04s, without the additional investment in time and effort. The use of UB-04 information for services that are not mature in a health care system may present unexpected challenges, necessitating a tradeoff with other methods of cost assignment.


Assuntos
Custos Hospitalares , Medicare , Estados Unidos , Preços Hospitalares , Análise Custo-Benefício
7.
J Cardiol ; 79(6): 734-739, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35016809

RESUMO

BACKGROUND: Automated optimization algorithm (AdaptivCRT; Medtronic, Mounds View, MN, USA) allowing automated optimization of cardiac resynchronization therapy (CRT), has been introduced. However, little is known concerning its cost-effectiveness. This study aims to evaluate the potential economic benefits of AdaptivCRT of CRT. METHODS: Markov modelling was informed by empirical data sourced from the AdaptivCRT Clinical Trial. Published meta-analyses were used to derive the impact of increasing response to hospitalization and mortality risks. Response was assessed via the clinical composite score. RESULTS: Deterministic results suggested a mean survival of 10.97 years with adaptive algorithms against 10.5 years without (+0.47 in favour of novel algorithms). Heart failure hospitalization costs were modelled to ¥1,382,753 (US $12,686) with novel devices against ¥1,524,747 (US $13,989) with previous technology models. Sensitivity analyses show CRT with Adaptive algorithm was projected to provide cost savings in all scenarios. CONCLUSIONS: The use of AdaptivCRT was projected to improve average patient survival and avoid costs in a Japanese healthcare setting.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Análise Custo-Benefício , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Resultado do Tratamento
8.
JACC Clin Electrophysiol ; 8(1): 101-111, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34600848

RESUMO

OBJECTIVES: This study aimed to identify risk factors for infection after secondary cardiac implantable electronic device (CIED) procedures. BACKGROUND: Risk factors for CIED infection are not well defined and techniques to minimize infection lack supportive evidence. WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention trial), a large study that assessed the safety and efficacy of an antibacterial envelope for CIED infection reduction, offers insight into procedural details and infection prevention strategies. METHODS: This analysis included 2,803 control patients from the WRAP-IT trial who received standard preoperative antibiotics but not the envelope (44 patients with major infections through all follow-up). A multivariate least absolute shrinkage and selection operator machine learning model, controlling for patient characteristics and procedural variables, was used for risk factor selection and identification. Risk factors consistently retaining predictive value in the model (appeared >10 times) across 100 iterations of imputed data were deemed significant. RESULTS: Of the 81 variables screened, 17 were identified as risk factors with 6 being patient/device-related (nonmodifiable) and 11 begin procedure-related (potentially modifiable). Patient/device-related factors included higher number of previous CIED procedures, history of atrial arrhythmia, geography (outside North America and Europe), device type, and lower body mass index. Procedural factors associated with increased risk included longer procedure time, implant location (non-left pectoral subcutaneous), perioperative glycopeptide antibiotic versus nonglycopeptide, anticoagulant, and/or antiplatelet use, and capsulectomy. Factors associated with decreased risk of infection included chlorhexidine skin preparation and antibiotic pocket wash. CONCLUSIONS: In WRAP-IT patients, we observed that several procedural risk factors correlated with infection risk. These results can help guide infection prevention strategies to minimize infections associated with secondary CIED procedures.


Assuntos
Desfibriladores Implantáveis , Infecções Relacionadas à Prótese , Antibioticoprofilaxia , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Humanos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco
9.
Int. j. cardiovasc. sci. (Impr.) ; 34(6): 692-701, Nov.-Dec. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1421759

RESUMO

Abstract Background: Implantable cardiac defibrillators (ICDs) therapy for primary prevention (PP) of sudden cardiac arrest (SCA) is well-established but underutilized globally. The Improve SCA study has identified a cohort of patients called 1.5 primary prevention (1.5PP), based on PP patients with the presence of documented risk factors: non-sustained ventricular tachycardia, frequent premature ventricular contractions, left ventricular ejection fraction < 25%, and pre-syncope or syncope. Objective: This study evaluated the cost-effectiveness of ICD therapy compared to no ICD among 1.5PP patients in the Brazilian public healthcare system. Methods: Modified inputs to a published Markov model were applied to compare costs and outcomes of ICD therapy to no ICD therapy from the Brazilian payer's perspective. Mortality and utility estimates were obtained from the IMPROVE SCA trial. Additional effectiveness inputs were sourced from the literature. Cost inputs were obtained from the Brazilian Unified Health System and the Ministry of Health. Costs were discounted at 4.7%; quality-adjusted life years (QALYs) were discounted at 1.45%. This study applied a willingness-to-pay (WTP) value of three times Brazil's gross domestic product (GDP) in 2017, R$105,723 (Brazilian Real). Results: The total discounted lifetime costs for ICD therapy were R$100,920 compared to R$43,866 for no ICD therapy. Total discounted QALYs for ICD therapy and no ICD therapy were 9.85 and 7.15, respectively. The incremental cost effectiveness ratio was R$21,156 per QALY and less than the R$105,723 WTP threshold. Results from sensitivity analyses were consistent with base case results. Conclusions: ICD therapy compared to no ICD therapy is cost-effective in the 1.5PP population in Brazil. (Int J Cardiovasc Sci. 2021; [online].ahead print, PP.0-0)

10.
J Invasive Cardiol ; 33(7): E522-E530, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34224381

RESUMO

BACKGROUND: The volume of atrial fibrillation (AF) catheter ablation procedures has increased to address the growing patient population with AF; however, the impact of cryoballoon ablation on electrophysiology (EP) lab throughput is under-studied when treating patients with persistent AF (PsAF). OBJECTIVE: To assess EP lab utilization associated with cryoballoon ablation for the treatment of patients with PsAF and to evaluate mechanisms that optimize hospital resources. METHODS: Procedural data derived from the STOP Persistent AF trial were input into a discrete event simulation to assess EP lab utilization during AF ablation procedures. Patient and physician delays and lab occupancy times were modeled in a nominal and efficient EP lab setting over 1000 days. Accounting for variation in procedural times, we evaluated the number of days in which preplanned pulmonary vein isolation (PVI) cases resulted in overtime or excess time for non-ablation EP cases within a given lab day. A sensitivity analysis determined the parameters that most strongly influenced EP lab throughput. RESULTS: Lab occupancy times for the Nominal Use (NU) case included 165 procedures, and the High-Efficiency Use (HEU) case was derived from 69 procedures conducted at sites with faster procedure times than average. The HEU case had shorter lab occupancy times than the NU case (158 ± 32 minutes vs 188 ± 51 minutes, respectively). In the NU case, a total of 2000 procedures were conducted, with 28 lab days (2.8%) extending into overtime and 900 lab days (90%) exhibiting excess time for a non-ablation EP case. In the HEU case, a total of 3000 procedures were conducted, with 87 lab days (8.7%) extending into overtime and 635 lab days (63.5%) exhibiting excess time for a non-ablation EP case. The model was most sensitive to lab occupancy duration and the time of day that overtime started. CONCLUSIONS: Cryoballoon ablation for the treatment of patients with PsAF confers EP lab efficiencies that can support 3 PVI cases in a lab day.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrofisiologia , Seguimentos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
11.
Europace ; 23(9): 1446-1455, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33755136

RESUMO

AIM: The Prevention of Arrhythmia Device Infection Trial (PADIT) infection risk score, developed based on a large prospectively collected data set, identified five independent predictors of cardiac implantable electronic device (CIED) infection. We performed an independent validation of the risk score in a data set extracted from U.S. healthcare claims. METHODS AND RESULTS: Retrospective identification of index CIED procedures among patients aged ≥18 years with at least one record of a CIED procedure between January 2011 and September 2014 in a U.S health claims database. PADIT risk factors and major CIED infections (with system removal, invasive procedure without system removal, or infection-attributable death) were identified through diagnosis and procedure codes. The data set was randomized by PADIT score into Data Set A (60%) and Data Set B (40%). A frailty model allowing multiple procedures per patient was fit using Data Set A, with PADIT score as the only predictor, excluding patients with prior CIED infection. A data set of 54 042 index procedures among 51 623 patients with 574 infections was extracted. Among patients with no history of prior CIED infection, a 1 unit increase in the PADIT score was associated with a relative 28% increase in infection risk. Prior CIED infection was associated with significant incremental predictive value (HR 5.66, P < 0.0001) after adjusting for PADIT score. A Harrell's C-statistic for the PADIT score and history of prior CIED infection was 0.76. CONCLUSION: The PADIT risk score predicts increased CIED infection risk, identifying higher risk patients that could potentially benefit from targeted interventions to reduce the risk of CIED infection. Prior CIED infection confers incremental predictive value to the PADIT score.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Adolescente , Adulto , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Atenção à Saúde , Eletrônica , Humanos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Estudos Retrospectivos , Fatores de Risco
12.
Heart Rhythm ; 18(7): 1142-1150, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33781980

RESUMO

BACKGROUND: Cardiac device procedures require tissue dissection to free existing device lead(s). Common techniques include blunt dissection, standard electrocautery, and low-temperature electrocautery (PlasmaBlade, Medtronic); however, data on the type of electrosurgical tool used and the development of procedure- or lead-related adverse events are limited. OBJECTIVE: The purpose of this study was to determine whether standard or low-temperature electrocautery impacts the development of an adverse event. METHODS: We evaluated patients enrolled in WRAP-IT (Worldwide Randomized Antibiotic EnveloPe Infection PrevenTion Trial) undergoing cardiac implantable electronic device (CIED) revision, upgrade, or replacement. All adverse events were adjudicated by an independent physician committee. Data were analyzed using Cox proportional hazard regression modeling. RESULTS: In total, 5641 patients underwent device revision/upgrade/replacement. Electrocautery was used in 5205 patients (92.3%) (mean age 70.6 ± 12.7 years; 28.8% female), and low-temperature electrocautery was used in 1866 patients (35.9%). Compared to standard electrocautery, low-temperature electrocautery was associated with a 23% reduction in the incidence of a procedure- or lead-related adverse event through 3 years of follow up (hazard ratio [HR] 0.77; 95% confidence interval [CI] 0.65-0.91; P = .002). After controlling for the number of active leads, degree of capsulectomy, degree of lead dissection, and renal dysfunction, low-temperature electrocautery was associated with a 32% lower risk of lead-related adverse events (HR 0.68; 95% CI 0.52-0.89; P = .004). These effects were consistent across a spectrum of lead-related adverse event types. CONCLUSION: This study represents one of the largest assessments of electrocautery use in patients undergoing CIED revision, upgrade, or replacement procedures. Compared to standard electrocautery, low-temperature electrocautery significantly reduces adverse effects from these procedures.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Eletrocoagulação/métodos , Marca-Passo Artificial/efeitos adversos , Idoso , Remoção de Dispositivo , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Temperatura
13.
J Med Econ ; 24(1): 173-180, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33471579

RESUMO

OBJECTIVE: The mortality benefit of implantable cardioverter defibrillators (ICDs) for primary prevention (PP) of sudden cardiac arrest (SCA) has been well-established, but ICD therapy remains globally underutilized. The results of the Improve SCA study showed a 49% relative risk reduction in all-cause mortality among ICD patients with 1.5 primary prevention (1.5PP) characteristics (patients with one or more risk factors, p < 0.0001). We evaluated the cost-effectiveness of ICD compared to no ICD therapy among patients with 1.5PP characteristics in three Latin American countries and analyzed the factors involved in cost-effectiveness. METHODS: We used a published Markov model that compares costs and outcomes of ICD to no ICD therapy from local payers' perspective and included country-specific and disease-specific inputs from the Improve SCA study and current literature. We used WHO-recommended willingness-to-pay (WTP) thresholds to assess cost-effectiveness and compared model outcomes between countries. RESULTS: Incremental costs per QALY (quality-adjusted life year) saved by ICD compared to no ICD therapy are Colombian Pesos COP$46,729,026 in Colombia, Mexican Pesos MXN$246,016 in Mexico, and Uruguayan Pesos UYU$1,213,614 in Uruguay in the base case scenario; all three figures are between 1-3-times GDP per capita for each country. One-way and probabilistic sensitivity analyses confirm the base case scenario results. Non-cardiac accumulated deaths are lower in Mexico, resulting in a comparatively increased cost-effective ICD therapy. LIMITATIONS: The Improve SCA study was not randomized, so clinical results could be biased; however, measures were taken to reduce this bias. Costs and benefits were modelled beyond the timeline of direct observation in the Improve SCA study. CONCLUSIONS: ICD therapy is cost-effective in Mexico and Uruguay and potentially cost-effective in Colombia for a 1.5PP population. Variability in ICER estimates by country can be explained by differences in non-cardiac deaths and cost inputs.


Assuntos
Desfibriladores Implantáveis , Análise Custo-Benefício , Morte Súbita Cardíaca/prevenção & controle , Humanos , América Latina , Prevenção Primária , Fatores de Risco
14.
PLoS One ; 15(11): e0241697, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33211698

RESUMO

OBJECTIVE: Implantable cardiac defibrillators (ICDs) for primary prevention (PP) of sudden cardiac arrest (SCA) are well-established but underutilized globally. The Improve SCA study has identified a cohort of patients called 1.5 primary prevention (1.5PP) based on PP patients with the presence of certain risk factors. We evaluated the cost-effectiveness of ICD therapy compared to no ICD among the PP population and the subset of 1.5PP patients in Taiwan. METHODS: A Markov model was run over a lifetime time horizon from the Taiwan payer perspective. Mortality and utility estimates were obtained from the literature (PP) and the IMPROVE SCA trial (1.5PP). Cost inputs were obtained from the Taiwan National Health Insurance Administration (NHIA), Ministry of Health and Welfare. We used a willingness-to-pay (WTP) threshold of NT$2,100,000, as established through standard WTP research methods and in alignment with World Health Organization recommendations. RESULTS: The total discounted costs for ICD therapy and no ICD therapy were NT$1,664,259 and NT$646,396 respectively for PP, while they were NT$2,410,603 and NT$905,881 respectively for 1.5PP. Total discounted QALYs for ICD therapy and no ICD therapy were 6.48 and 4.98 respectively for PP, while they were 10.78 and 7.71 respectively for 1.5PP. The incremental cost effectiveness ratio was NT$708,711 for PP and NT$441,153 for 1.5PP, therefore ICD therapy should be considered cost effective for PP and highly cost effective for 1.5PP. CONCLUSIONS: ICD therapy compared to no ICD therapy is cost-effective in the whole PP population and highly cost-effective in the subset 1.5PP population in Taiwan.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Prevenção Primária/métodos , Feminino , Humanos , Masculino , Cadeias de Markov , Anos de Vida Ajustados por Qualidade de Vida , Fatores de Risco
15.
Circ Arrhythm Electrophysiol ; 13(10): e008503, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32915063

RESUMO

BACKGROUND: In the WRAP-IT trial (Worldwide Randomized Antibiotic Envelope Infection Prevention), adjunctive use of an absorbable antibacterial envelope resulted in a 40% reduction of major cardiac implantable electronic device infection without increased risk of complication in 6983 patients undergoing cardiac implantable electronic device revision, replacement, upgrade, or initial cardiac resynchronization therapy defibrillator implant. There is limited information on the cost-effectiveness of this strategy. As a prespecified objective, we evaluated antibacterial envelope cost-effectiveness compared with standard-of-care infection prevention strategies in the US healthcare system. METHODS: A decision tree model was used to compare costs and outcomes of antibacterial envelope (TYRX) use adjunctive to standard-of-care infection prevention versus standard-of-care alone over a lifelong time horizon. The analysis was performed from an integrated payer-provider network perspective. Infection rates, antibacterial envelope effectiveness, infection treatment costs and patterns, infection-related mortality, and utility estimates were obtained from the WRAP-IT trial. Life expectancy and long-term costs associated with device replacement, follow-up, and healthcare utilization were sourced from the literature. Costs and quality-adjusted life years were discounted at 3%. An upper willingness-to-pay threshold of $150 000 per quality-adjusted life year was used to determine cost-effectiveness, in alignment with the American College of Cardiology/American Heart Association practice guidelines and as supported by the World Health Organization and contemporary literature. RESULTS: The base case incremental cost-effectiveness ratio of the antibacterial envelope compared with standard-of-care was $112 603/quality-adjusted life year. The incremental cost-effectiveness ratio remained lower than the willingness-to-pay threshold in 74% of iterations in the probabilistic sensitivity analysis and was most sensitive to the following model inputs: infection-related mortality, life expectancy, and infection cost. CONCLUSIONS: The absorbable antibacterial envelope was associated with a cost-effectiveness ratio below contemporary benchmarks in the WRAP-IT patient population, suggesting that the envelope provides value for the US healthcare system by reducing the incidence of cardiac implantable electronic device infection. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02277990.


Assuntos
Antibacterianos/economia , Antibioticoprofilaxia/economia , Dispositivos de Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Custos de Medicamentos , Implantação de Prótese/economia , Infecções Relacionadas à Prótese/economia , Implantes Absorvíveis/economia , Antibacterianos/uso terapêutico , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Tomada de Decisão Clínica , Redução de Custos , Análise Custo-Benefício , Árvores de Decisões , Desfibriladores Implantáveis/efeitos adversos , Humanos , Modelos Econômicos , Estudos Multicêntricos como Assunto , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/prevenção & controle , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
17.
Circ Arrhythm Electrophysiol ; 13(5): e008280, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32281393

RESUMO

BACKGROUND: Current understanding of the impact of cardiac implantable electronic device (CIED) infection is based on retrospective analyses from medical records or administrative claims data. The WRAP-IT (Worldwide Randomized Antibiotic Envelope Infection Prevention Trial) offers an opportunity to evaluate the clinical and economic impacts of CIED infection from the hospital, payer, and patient perspectives in the US healthcare system. METHODS: This was a prespecified, as-treated analysis evaluating outcomes related to major CIED infections: mortality, quality of life, disruption of CIED therapy, healthcare utilization, and costs. Payer costs were assigned using medicare fee for service national payments, while medicare advantage, hospital, and patient costs were derived from similar hospital admissions in administrative datasets. RESULTS: Major CIED infection was associated with increased all-cause mortality (12-month risk-adjusted hazard ratio, 3.41 [95% CI, 1.81-6.41]; P<0.001), an effect that sustained beyond 12 months (hazard ratio through all follow-up, 2.30 [95% CI, 1.29-4.07]; P=0.004). Quality of life was reduced (P=0.004) and did not normalize for 6 months. Disruptions in CIED therapy were experienced in 36% of infections for a median duration of 184 days. Mean costs were $55 547±$45 802 for the hospital, $26 867±$14 893, for medicare fee for service and $57 978±$29 431 for Medicare Advantage (mean hospital margin of -$30 828±$39 757 for medicare fee for service and -$6055±$45 033 for medicare advantage). Mean out-of-pocket costs for patients were $2156±$1999 for medicare fee for service, and $1658±$1250 for medicare advantage. CONCLUSIONS: This large, prospective analysis corroborates and extends understanding of the impact of CIED infections as seen in real-world datasets. CIED infections severely impact mortality, quality of life, healthcare utilization, and cost in the US healthcare system. Registration: URL: https://www.clinicaltrials.gov Unique Identifier: NCT02277990.


Assuntos
Antibacterianos/economia , Antibacterianos/uso terapêutico , Antibioticoprofilaxia/economia , Desfibriladores Implantáveis/economia , Custos de Cuidados de Saúde , Recursos em Saúde/economia , Marca-Passo Artificial/economia , Infecções Relacionadas à Prótese/economia , Infecções Relacionadas à Prótese/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/efeitos adversos , Antibioticoprofilaxia/efeitos adversos , Causas de Morte , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/economia , Custos de Medicamentos , Planos de Pagamento por Serviço Prestado/economia , Feminino , Gastos em Saúde , Custos Hospitalares , Humanos , Tempo de Internação/economia , Masculino , Medicare/economia , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Readmissão do Paciente/economia , Estudos Prospectivos , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Qualidade de Vida , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
18.
Heart Rhythm ; 17(8): 1393-1397, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32247833

RESUMO

Pacemaker-related infections remain a constant concern due to increased risk of patient morbidity and mortality. Although transvenous pacemakers are expected to have an infection rate ranging from 0.77% to 2.08%, no cases of leadless pacemaker infection have been reported in clinical trials enrolling more than 3000 patients. Many potential reasons why leadless pacemakers may be resistant to infection include the absence of a subcutaneous pocket and leads, reduced skin and glove contact, size, location, and device material. This review summarizes the current state of evidence regarding the apparent infection resistance of leadless pacemakers.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco/fisiopatologia , Marca-Passo Artificial , Arritmias Cardíacas/fisiopatologia , Desenho de Equipamento , Humanos
19.
J Cardiovasc Electrophysiol ; 31(3): 712-717, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32009284

RESUMO

INTRODUCTION: Infections of cardiac implantable electronic devices remain a prevalent health concern necessitating the advent of novel preventative strategies. Based on the observation that bacterial infections of the Micra transcatheter pacemaker device are extremely rare, we examine the effect of parylene coating on bacterial adhesion and growth. METHODS: Bacterial growth was compared on polyurethane coated, bare, or parylene coated titanium surfaces. Eight test samples per bacterial species and material combination were incubated with Staphylococcus Aureus or Pseudomonas aeruginosa for 24 hours and then assayed for bacterial growth. The surface contact angle was also characterized by measuring the angle between the tangent to the surface of a liquid droplet made with the surface of the solid sample. RESULTS: The mean bacterial colony counts were significantly reduced for both parylene coated titanium versus bare samples (3.69 ± 0.27 and 4.80 ± 0.48 log[CFU/mL] respectively for S. aureus [P < .001] and 5.51 ± 0.27 and 6.08 ± 0.11 log[CFU/mL] respectively for P. aeruginosa [P < .001]), and for parylene coated titanium versus polyurethane samples (4.27 ± 0.42 and 5.40 ± 0.49 log[CFU/mL] respectively for S. aureus [P < .001] and 4.23 ± 0.42 and 4.84 ± 0.32 log[CFU/mL] respectively for P. aeruginosa [P = .006]). Parylene coated titanium samples had a higher contact angle compared with bare titanium, but lower compared with polyurethane (mean contact angle 87.5 ± 3.1 degrees parylene, 73.3 ± 3.7 degrees titanium [P < .001 vs parylene], and 94.8 ± 3.7 degrees polyurethane [P = .002 vs parylene]). CONCLUSIONS: Parylene coating significantly reduced the ability of bacteria to grow in colony count assays suggesting that this could contribute to the reduction of bacterial infections of Micra transcatheter pacemakers.


Assuntos
Antibacterianos/farmacologia , Aderência Bacteriana/efeitos dos fármacos , Materiais Revestidos Biocompatíveis , Contaminação de Equipamentos , Marca-Passo Artificial/microbiologia , Polímeros/farmacologia , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Xilenos/farmacologia , Contagem de Colônia Microbiana , Pseudomonas aeruginosa/crescimento & desenvolvimento , Staphylococcus aureus/crescimento & desenvolvimento
20.
Pacing Clin Electrophysiol ; 42(8): 1105-1110, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31232461

RESUMO

BACKGROUND: The Micra clinical trials have enrolled more than 2500 patients without any reported device-related infections that required removal during follow-up. Leadless pacemakers might be more resistant to bacterial seeding due to smaller surface area and a greater tendency for encapsulation. OBJECTIVE: To analyze the incidence and outcomes of serious infectious events (SIEs: bacteremia or endocarditis) that developed during follow-up in patients with history of Micra leadless pacemaker implantation. METHODS: SIE and outcomes were characterized based upon adverse event reports. Among 720 patients implanted with Micra in the investigational device exemption trial, we identified 16 patients who had documented 21 SIEs during follow-up. RESULTS: Among patients with SIEs, mean age was 71.9 ± 11.7 years. SIEs occurred at a mean 4.8 ± 4.5 months after implant and patients were followed for 13.1 ± 9.1 months after documentation of SIE. All events were adjudicated as unrelated to the Micra device or procedure. Bacteremia was documented to be related to a gram-positive organism in 13 events (seven Staphylococcus, three Streptococcus, two Enterococcus, and one uncharacterized gram-positive bacteria), and gram-negative organisms in three events. In five events, the type of organism was not characterized (two patients with endocarditis). No persistent cases of bacteremia after antibiotic cessation were seen over the duration of follow-up CONCLUSION: In this small series of Micra patients who developed SIEs postimplant, the occurrence of bacteremia and/or endocarditis did not appear to lead to persistent bacteremia off antibiotics; most events resolved with antibiotic treatment.


Assuntos
Bacteriemia/epidemiologia , Endocardite/epidemiologia , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Bacteriemia/etiologia , Estudos de Coortes , Endocardite/etiologia , Desenho de Equipamento , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...